91大神

91大神Water Technologies & Solutions

Sievers M9 On-Line TOC Analyzer

Continuous, accurate monitoring with broad, linear TOC range

The Sievers M9 On-Line Analyzer offers excellent low-level sensitivity for ultrapure water analysis and high-level capability for cleaning validation or other challenging water samples. It’s proprietary Integrated On-Line Sampling (iOS) System enables easy introduction of external standards and samples without removing the instrument from the continuous sample source. With Sievers unique technology, the M9 On-Line is immune to false positive and false negatives that trouble non-membrane based TOC instruments.

Explore how to increase productivity with continuous monitoring

Designed for continuous monitoring of waters from ultrapure to potable, the M9 On-Line provides unparalleled accuracy, precision, and speed across a dynamic operating range of 0.03 ppb to 50 ppm. It supports compliance with pharmacopeia water testing or can be used for cleaning validation and other online applications. In Turbo mode, the M9 provides analysis every four-seconds, providing up-to-the-second results for better control. Sievers M9 Analyzers meet or exceed the most common pharmaceutical regulatory requirements for TOC analysis and data integrity.

Features & Benefits

M9 On-Line Features & Benefits

  • Two-minute sample analysis time
  • Continuous monitoring with the ability to easily introduce discrete grab samples and standards
  • Wall-mounted with an IP-45 rated enclosure to withstand demanding environments
  • Automated operations, such as calibration and data analysis?
  • Autoreagent feature automatically establishes optimal flow rates for each sample
  • Minimal preventive maintenance (typically just a few hours per year)
  • 12-month calibration stability
  • Optional Turbo mode for four-second analysis

Specifications

M9 On-Line Specifications

Operating Specifications*

Range 0.03 ppb to 50 ppm
Precision < 1% RSD ?
Accuracy ± 2% or ± 0.5 ppb, whichever is greater
Display Readout 3 significant digits
Sample Type On-line continuous or discrete grab sample
Calibration Typically stable for 12 months
Analysis Time 2 minutes (4 seconds with the optional Turbo mode)
Sample Temperature** 5–95 °C (41–203 °F)
Ambient Temperature 5–40 °C (41–104 °F)
Sample Pressure 100 psig
On-Line Flow Rate >50 mL/min (for on-line mode)
Instrument Sample?
Flow Rate
0.5 mL/min

Analyzer Specifications

Outputs 4-20 mA outputs (3); alarm outputs (4); binary input (1); USB device port (1); USB host ports (2); Modbus TCP/IP
Display 7" WVGA 800X480 pixel, Color LCD with touch-screen
Power 100 - 240 V~, 50 -60 Hz, 100 VA
Fuses Replace with same type and size fuse: T 1.6 A 250 VAC Fuse (Slow Blow), size 5 X 20 mm appliance inlet
Dimensions H: 54.9 cm (21.6 in); W: 45.0 cm (17.7 in); D: 26.5 cm (10.4 in)
Weight 15.8 kg (34.9 lb)
Enclosure Rating IP-45
Safety Certifications ETL, CE (see?Declaration of Conformity)?

Environment

Maximum Relative Humidity 0 - 95%, non-condensing
Maximum Altitude 3,000 m (9.800 ft)
Pollution Degree 2

The UV lamp inside this product contains mercury and must be recycled or disposed of in accordance with local, state, and federal laws.

* Stated analytical performance is achievable under controlled laboratory conditions that minimize operator and standards errors.
**Sample temperature above 60 °C requires optional PVDF iOS

Specs (Turbo Mode)

M9 On-Line Turbo Specifications

Operating Specifications*

Range 0.20 ppb to 10 ppm
Precision 2% RSD
Accuracy ± 10% or ±10 ppb whichever is greater
Display Readout 3 significant digits
Sample Type On-line, Grab
Calibration Typically stable for 12 months
Analysis Time 4 seconds
Response Time 3.25 minutes
Sample Temperature 5–95 °C (41–203 °F)
Ambient Temperature 10–40 °C (50–104 °F)
Sample Pressure 100?psi
Sample Flow Rate 30–300 mL/min (for on-line mode)
Instrument Sample?
Flow Rate
1.1 mL/min

Analyzer?Specifications

Outputs 4-20 mA outputs (3); alarm outputs (4); binary input (1); USB device port (1), USB host ports (2); Ethernet (1)
Display 7” WVGA 800x480 pixel, Color LCD w/touch-screen
Power Universal Power Supply: 100–240 ± 10% VAC, 50 W, 50/60 Hz
Dimensions H: 54.9 cm (21.6 in); W: 45.0 cm (17.7 in); D: 26.5 cm (10.4 in)
Weight 15.8 kg (34.9 lb)
Safety Certifications ETL, CE
Enclosure Rating IP-45

Consumables

UV Lamp 6 months
Acid Reagent As needed, typically 6 months
Oxidizer Reagent As needed, typically 3-month stability

*Stated analytical performance is achievable under controlled laboratory conditions that minimize operator and standards errors.

Accessories

M9 On-Line Options & Accessories

  • Inorganic Carbon Remover (ICR): Improves TOC accuracy for samples with high inorganic carbon levels

  • Turbo Mode: Provides four-second analysis time?

  • DataGuard Software: Full compliance support for 21 CFR Part 11 and Annex 11