Sievers TOC-R3 Online TOC Analyzer
You can confidently and quickly detect leaks, ensure effluent compliance, and improve quality and process control when you have dependable data. The Sievers TOC-R3 Online Total Organic Carbon (TOC) and Total Nitrogen (TN) Analyzer uses robust, high-temperature, non-catalytic combustion technology to provide reliable and responsive data for industrial processes. It uses 1200 ℃ complete combustion oxidation and has minimal maintenance needs, low chemical consumption, and advanced data management and software. With enhanced troubleshooting using predictive maintenance and remote control, you’ll avoid downtime and be ready to take action. Offering seamless operation, minimal maintenance, and enhanced uptime, the TOC-R3 is highly efficient for various monitoring applications.?
?
? ? ? ? ?Download the eBook
?
TOC-R3: Robust, Reliable and Responsive
The TOC-R3 is robust because it provides superior analytical performance and status monitoring across a broad analytical range and protection classes for environments while having low maintenance needs. The instrument is reliable in its automated calibration, self-cleaning, and check standard capability, allowing for low system downtime. The revolutionary technology is responsive with a rapid cycle time as well as an optional leak detection mode and wide-range detector.
Features & Benefits
- Catalyst-free, high temperature combustion offering complete oxidation at 1,200 °C
- Minimal and simple maintenance due to modular design and status monitoring
- Self-cleaning and automated rinsing capability to tackle even the harshest samples
- Low chemical consumption for safety and lower cost of ownership
- Advanced data management and intuitive software for straightforward user experience
- Predictive maintenance and remote control for enhanced troubleshooting
Specifications
Operating Specifications |
|
---|---|
Analysis Modes | Standard:TC, NPOC Option: TIC, TNb?, TOCdiff, POC/VOC, |
Ranges |
TC/Carbon : 0-10; 0-200; 0-2,000; 0-10,000; with Dilution 0-50,000 mg/L; Wide Range: 0-200; 200-20,000 mg/L; |
Options/Accessories | Leak Detection (for TC only), Sample Stream 2, Particulate Sampler, Air Box, Air Scrubber, Communication Box, Mounting Rack, PID Detector* (for POC/VOC) or ECD Detector* (for TNb) |
Features |
Auto Calibration, Dilution, Check Function, Auto Rinse, Connectivity (Remote Control), Predictive Maintenance |
Precision? | +/-2% End of Detector Range? |
Linearity | R2 ≥0.997? |
LOD | <1 ppm? |
Analysis Time | 3-5 min typically |
Smallest Inner Diameter (ID) | 2 mm smallest tubing diameter |
Capacity? | Up to 21 samples in duplicate with positive product controls? |
Salt Tolerance | 3-5% NaCl |
Carrier Gas | CO2 free air < 1 ppm CO2 and <0.1 ppm hydrocarbon: 100-200 kPa @ 30-50L/hr flow rate (Optional: Air box) |
Sample Temperature | 2-60 °C (35.6-140 °F) |
Ambient Temperature | 2-40 °C (35.6-104 °F) |
Minimum Sample Flow Rate |
100 mL/min without Particulate Sampler or 11.7-50 LPM (3.1-13.2 US gal/min) with Particulate Sampler |
Drain | Gravity, No back pressure (< 7 kPa, 0.07 Bar, 1 psig) |
Analyzer Specifications |
|
Communication protocols | OPC UA, Modbus?TCP/IP |
Inputs | Digital Input (4) |
Display | 7 in. Touch panel |
Power | AC 110 – 230 V ±10 V 50/60 Hz,?400-600 VA |
Alarm Relays | Warnings, errors, measurement limit, instrument status |
Outputs | OPC UA, Ethernet, 4-20 mA (6) |
Installation/Overvoltage Category |
II |
Available Configurations | Standard: Single-Stream; Option: Second Stream |
Dimensions | 900 H x 644.3 W x 354.5 D mm (35.5 H x 25.4 W x 14 D in) |
Weight | 55 kg, (121 lb) |
Safety Certifications | CE, UL, CSA |
Regulatory | DIN EN 1484 /ISO 8245, EPA 415.3, SM 5310B, ASTM D5173, HJ 501, DIN EN 12260 |
Environment |
|
Enclosure | Standard: IP-54; Option: ATEX Zone 1 & 2 T4, IECEx Zone 1 & 2 T4, C1D2 |
Maximum Relative Humidity | Up to 85%, non-condensing |
Options & Accessories
- Total Nitrogen with simple electrochemical detector (ECD)
- Volatile/Purgeable Organic Carbon with reliable photoionization detector (PID)
- TOC Differential (TOC = TC - IC)
- Leak Detection Mode for early alert of a leak?
- Second Stream
- Communication Box for Streamlined SCADA connections
- Air Box as Standalone Carrier Gas System
- Particulate Sampler for high particulate loaded streams
- Mounting Rack